Cleaning Cells Tips and Tricks

Cleaning Cells – Avoid These Mistakes – Electrostatic Mistbuster & Trimist Units

Tips for Cleaning Cells There comes a time where your equipment is running smoothly and then all of a sudden everything comes to a standstill. Cleaning cells in sources capture equipment on a CNC machine is crucial to reducing machine downtime. Soak the cells using a non-etching soap that will not degrade the aluminum.  Cell.

By: asc2863
In: General Maintenance
0
Read MoreRead More
Indicator Light Blinking Problem

Is Your Indicator Light Blinking on Your Industrial Air Filtration Unit

Blinking Light on your MistBuster, Tri-Mist or Coolblaster? What to do When the Indicator Light Blinks? A Ground in the Unicell Assembly.  The metal fins within the unicell cannot touch one another or the electrical current running through the charged cell will ground out.  When the indicator light is blinking please follow the procedure below.

By: asc2863
In: Common Problems
0
Read MoreRead More
MistBuster 2" Baffle Solution for Air Flow

Should I Use a Post HEPA Filter on my MistBuster?

How the Airflow Could be Reduced In many factories I see the large post HEPA filter sitting on top of many Mistbuster and Trimist electrostatic air filtration units. I would say that in probably 80 – 90% of these applications the HEPA filter is actually causing more of a problem then a solution. The main.

By: asc2863
In: Air Flow, HEPA
0
Read MoreRead More
Cleaning Mistbuster and Trimist Cells

Washing MistBuster and Tri-Mist Cells – Do’s & Don’ts

Getting The Cells Cleaned Effectively to Ensure Proper Operation 1. The collection plates that are stacked closely together which make up each unicell assembly have a large surface area and can only be cleaned by submersion in a non-etching cell soap. (Cell soak 2000) If the soap used is too acidic, then the cell will.

By: asc2863
In: General Maintenance
0
Read MoreRead More
Oil Residue on Electrostatic Cells

Reduced Air Flow – Slippery Factory Floors

The Residue Ends Up Everywhere In many factories I find a thin oil residue on all the equipment, floors, and sometimes even the boxes for finished products. I see that all the CNC units have Air Filtration units attached like Tri-Mist and MistBusters, and in many cases they even have HEPA filters attached. The HEPA.

By: asc2863
In: Common Problems
0
Read MoreRead More
Cleaning Electrostatic Precipitators an Wastewater

Should I Outsource the Cleaning of Electrostatic Cells?

Mistbuster, CoolBlaster, SmogHog & Trion It all depends on how many units you have vs. manpower and equipment needed to clean them well, and be able to do it consistently and with efficiency. There are companies that wash electrostatic cells. It is important however to verify that the company can clean the cells without damaging.

By: asc2863
In: General Maintenance
0
Read MoreRead More
Mistbuster Safety Test Button

Mistbuster & Coolblaster Maintenance Procedure with Service Tips

The Key is Routine Maintenance Mistbuster & Coolblaster series units are source capture air filtration units that remove oil mist and smoke from CNC cabinets. These units come in different sizes (500, 750, 850,Quad, 2000) and have odor control post filters which can be added on. Electrostatic units can remove particulate in the air as.

By: asc2863
In: General Maintenance
0
Read MoreRead More
Cleaning Frequency Electrosatic Precipitator

How Often Electrostatic Filters Need Cleaning?

Do I Need to Maintain my MistBuster & TriMist Cool Blaster Air Filtration Units? Yes. The maintenance frequency on an industrial air purification unit is extremely important. Many manufacturers recommend cleaning the electrostatic filters four times per year. Unlike a media type filter, electrostatic air filtration units such as SMOG HOG or TRION, MISTBUSTER or.

By: asc2863
In: General Maintenance
1
Read MoreRead More